SUNGROW-HYD-SH6.0RS (ADA)
SUNGROW-HYD-SH6.0RS (ADA)

SUNGROW-HYD-SH6.0RS (ADA)

Regular price$2,499.00
/

  • In stock, ready to ship
  • Backordered, shipping soon

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

SUNGROW-HYD-SH6.0RS

  • FLEXIBLE APPLICATION

    80~460 V wide battery voltage range 

    Ideal for both retrofitting and new installations 

    Built-in smart PID recovery function  

  • ENERGY INDEPENDENCE

    Seamless transition to backup mode, for protection against power outages 

    Fast Charging or discharging, enabling higher self-consumption results 

    Built-in EMS with advanced customization  

  • USER FRIENDLY SETUP

    Plug and play installation

    iSolarCloud monitoring available on App and Web 

    Lightweight and compact, optimized for heat-dissipation  

  • SMART MANAGEMENT

    Real time data (10 seconds refresh sample) 

    24/7 live monitoring both online and with integrated display 

    Online IV curve scan and diagnosis  


  • TECH SPECS

Specification Description
Type designation SH6.0RS
Input (DC)
Recommended max. PV input power 13000 Wp
Max. PV input voltage 600 V
Min. operating PV voltage / Start-up input voltage 40 V / 50 V
Rated PV input voltage 360 V
MPP voltage range 40V – 560 V
No. of independent MPP inputs 2
No. of PV strings per MPPT 1 / 1
Max. PV input current 32 A (16 A / 16 A)
Max. DC short-circuit current 40 A (20 A / 20 A)
Max. current for input connector 20 A
Battery Data
Battery type Li-ion battery
Battery voltage 80 V - 460 V
Max charge / discharge current 30 A / 30 A
Max charge / discharge power 6600 W
Input / Output ( AC )
Max. AC power from grid 13000 VA
Rated AC output power 6000 W
Max. AC output apparent power 6000 VA
Rated AC output apparent power 6000 VA
Rated AC output current (at 230V) 26.1 A
Max. AC output current 27.3 A
Rated AC voltage 230 V
AC voltage range 154 V – 276 V
Rated grid frequency 50 Hz / 60 Hz
Grid frequency range 45 Hz – 55 Hz / 55 Hz – 65 Hz
Harmonic (THD) < 3% (of rated power)
Power factor at rated power / Adjustable power factor > 0.99 at default value at rated power
Feed-in phases / connection phases 1 / 1
Backup Data (on-grid mode)
Rated output power for backup load 6000 W
Rated output current for backup load 27.3 A
Backup Data (off-grid mode)
Rated voltage 230V (±2%)
Rated grid frequency 50 Hz / 60 Hz (±0.2%)
Output voltage harmonic (THD) < 2%
Switch time to emergency mode < 10 ms
Rated output power 6000 W / 6000 VA
Peak output power 8400 VA, 10 s
Efficiency
Max. efficiency 97.7%
European efficiency 97.3%
Protection & Function
Grid monitoring Yes
DC reverse polarity protection Yes
AC short circuit protection Yes
Leakage current protection Yes
DC switch (solar) Yes
DC Overcurrent Protection (Battery) Yes
Surge Protection DC Type II / AC Type II
PID recovery function Yes
Parallel operation on grid port / Max. No of inverters Master-slave mode / 3
Battery input reverse polarity protection Yes
General Data
Topology (Solar / Battery) Transformerless / Transformerless
Degree of protection IP65
Dimensions (W * H * D) 490 mm * 340 mm * 170 mm
Weight 18.5 kg
Mounting method Wall-mounting bracket
Operating ambient temperature range -25 ℃ – 60 ℃
Allowable relative humidity range (Non-condensing) 0% – 100%
Cooling method Natural convection
Max. operating altitude 4000 m
Display LED digital display & LED indicator
Communication RS485 / Ethernet / WLAN / CAN
DI / DO DI * 4 / DO * 1 / DRM
DC connection type MC4 (PV) / Evo2 Compatible (Battery)
AC connection type Plug and Play ***
Grid compliance IEC 62109-1/2, IEC 62477-1, AS/NZS 4777.2:2020
Country of manufacture China

You may also like